7T proton MR spectroscopy spots brain changes in MS patients

2022 01 04 22 52 4693 2022 01 05 Mri Brain Changes Figure3 20220104224623

Proton MR spectroscopy can identify changes in the brains of people with multiple sclerosis (MS), according to a study published January 4 in Radiology.

The findings could translate to earlier diagnosis and treatment, senior author Wolfgang Bogner, PhD, of the Medical University of Vienna in Austria said in a statement released by the university.

"If confirmed in longitudinal clinical studies, this new neuroimaging technique could become a standard imaging tool for initial diagnosis, for disease progression and therapy monitoring of multiple sclerosis patients, and, in concert with established MRI, might contribute to neurologists' treatment strategies," he said.

MS affects the central nervous system and can cause fatigue, pain, and coordination problems, the group noted. Almost 3 million people around the world suffer from the condition, and there's no cure -- only treatments such as physical therapy and medication to slow its progression.

One of the ways MS manifests is as white-matter lesions in the brain, which are associated with a loss of myelin, a protective coating around white matter fibers. But these lesions represent macroscopic damage, noted lead author Eva Heckova, PhD, and colleagues: It would benefit patients to be able to identify earlier, microscopic changes in the brain suggestive of MS.

That's why proton MR spectroscopy shows promise, since it can identify substances produced by a person's metabolism that could indicate the presence of MS.

In the current study, proton MR spectroscopy was performed on a 7-tesla scanner using a technique called free-induction decay MR spectroscopic imaging, with 2 x 2-mm in-plane spatial resolution. For the study, the investigators used the technique to compare differences in normal-appearing white matter and cortical gray matter in the brains of 65 MS patients and 20 healthy controls.

Metabolic maps showing the ratio of myo-inositol to N-acetylaspartate (mI/NAA) clearly depict small subcortical or juxtacortical lesions (circles) that appear inconspicuous at T1-weighted MRI (T1w)/fluid-attenuated inversion-recovery (FLAIR) imaging.Metabolic maps showing the ratio of myo-inositol to N-acetylaspartate (mI/NAA) clearly depict small subcortical or juxtacortical lesions (circles) that appear inconspicuous at T1-weighted MRI (T1w)/fluid-attenuated inversion-recovery (FLAIR) imaging.

The group found the following brain differences in patients with MS:

  • Lower levels of an amino acid derivative called N-acetylaspartate, which is associated with compromised integrity of neurons
  • Higher levels of myo-inositol, which is involved in cell signaling; increased levels indicate significant inflammatory disease activity
  • Metabolic changes in normal-appearing white matter and cortical gray matter

The brain changes this MR technique illuminated could have important clinical implications, according to Heckova.

"Some neurochemical changes, particularly those associated with neuroinflammation, occur early in the course of the disease and may not only be correlated with disability, but also be predictive of further progression such as the formation of multiple sclerosis lesions," she said.

In an accompanying commentary, Peter Barker, PhD, of Johns Hopkins University in Baltimore cautioned that although proton MR spectroscopy could be an effective way to identify MS earlier, it may be difficult to incorporate it into clinical practice.

"The number of 7-tesla scanners worldwide is tiny compared with 1.5 or 3-tesla, and the cost of installing and operating these systems is steep," he said. "Thus, for the near future at least ... both MRI and MR spectroscopy at 7-tesla are likely to be mainly of use for research studies in MS, where the best possible resolution and highest information content are needed."

Page 1 of 605
Next Page