Echocardiographers face an increased risk of radiation exposure when imaging during heart disease interventions, researchers have warned in a study published July 7 in JAMA Network Open.
A U.S. group at a hospital system in Michigan measured head-level radiation doses experienced by echocardiographers during certain procedures that require them to stand near the radiation source and patient. The team found that echocardiographers providing imaging guidance received more than 11 times the radiation dose of the interventional cardiologists performing the procedures.
"These comparatively increased radiation doses reveal a previously underrecognized occupational radiation exposure risk, which has important ramifications for the rapidly expanding field of interventional echocardiography," wrote corresponding author Dr. David McNamara, a cardiologist at Spectrum Health in Grand Rapids.
Echocardiographers are imaging specialists who help physicians diagnose and treat heart problems. For instance, they operate ultrasound equipment that provides 2D or 3D images of the heart and its chambers during procedures like left atrial appendage occlusion (LAAO) treatment for stroke prevention and transcatheter edge-to-edge mitral valve repair (TEER).
Both LAAO and TEER are typically performed under the guidance of fluoroscopy and transesophageal echocardiography, which has resulted in the addition of an interventional echocardiographer as an integral member of the heart team at many hospitals.
Prior studies have shown that interventional cardiologists performing LAAO and TEER are at risk of radiation exposure due to fluoroscopic imaging used to help guide the procedures, yet data on radiation exposure to echocardiographers are lacking, according to the authors.
To elucidate the issue, McNamara and colleagues measured radiation doses from interventional echocardiographers and interventional cardiologists at Spectrum Health's Frederik Meijer Heart and Vascular Institute during 30 sequential LAAO and 30 sequential TEER procedures from July 2016 to January 2018. They measured personal dose equivalents per case using real-time radiation dosimeters.
Both the echocardiographers and interventional cardiologists wore traditional lead apparel, consisting of a lead skirt, apron, and thyroid collar. In addition, lead shields were positioned between the patients and the heart team members in all cases.
According to the findings, interventional echocardiographers were observed to have median head-level radiation doses that were threefold greater during LAAO and 11.7-fold greater during TEER than for interventional physicians.
During LAAO procedures, the median radiation dose was 10.6 µSv among interventional echocardiographers and 3.5 µSv among interventional cardiologists. During TEER, interventional echocardiographers received a median radiation dose of 10.5 µSv, which was higher than the median radiation dose of 0.9 µSv received by interventional cardiologists.
| Radiation dose during interventional cardiology procedures | ||
| Type of procedure | Interventional cardiologists | Interventional echocardiographers |
| LAAO | 3.5 µSv | 10.6 µSv |
| TEER | 0.9 µSv | 10.5 µSv |
"The findings of this study may have important occupational health implications for the rapidly expanding field of interventional echocardiography and for the structural heart team," the authors wrote.
Ultimately, the study shows echocardiographers may be vulnerable to the level of long-term radiation exposure seen in cardiac catheterization laboratories. This exposure has been associated with multiple adverse health effects among interventional cardiologists, such as premature cataract formation, early carotid atherosclerosis, and possibly left-sided brain malignant tumors, the authors wrote.
The occupational risks for echocardiographers will depend on several factors, including the annual volume of TEE-guided fluoroscopic procedures, the radiation doses received during each procedure, the quality of the fluoroscopy imaging used, and the radiation safety practices of individual institutions, they added.
"Additional studies are needed to determine whether thicker shields or alternative shielding configurations (such as suspended lead suits) would result in lower radiation doses than those observed," McNamara and colleagues concluded.
















![Examples of ultrasound findings and techniques. (A) Images in a 39-year-old male patient with a mass in the left thigh. The mass is heterogeneous on the B-mode US image (compared with the patient in D) and showed increased microvascularity (superb microvascular imaging [SMI]) and shear-wave elastography (SWE) values. Undifferentiated pleomorphic sarcoma was diagnosed at biopsy (with pleomorphic rhabdomyosarcoma in surgical specimen). (B) Images in an 18-year-old male patient with a mass in the left leg. The mass is hypoechoic on the B-mode image, with no other findings suggestive of malignancy. The lesion is in contact with the cortex of the tibia, which is slightly irregular. CT revealed a doubtful anteromedial tibial erosion. The microvascular study demonstrated high vascularization, suggestive of malignancy. Periosteal Ewing sarcoma was diagnosed with both histologic and immunohistochemical confirmation. (C) Images in a 69-year-old female patient with a lump growing on the outside of the left leg. Multiple SWE examinations were performed (please note the high values obtained in the measurements, whereas the color map highlights the stiffness relative to adjacent tissues). SMI showed areas of increased vascularization to target for sampling. Undifferentiated spindle cell sarcoma was diagnosed at biopsy, with residual leiomyosarcoma in the surgical specimen after neoadjuvant therapy. (D) Images in a 56-year-old female patient with a mass in the right thigh. The mass is heterogeneous at both B-mode ultrasound (similar to patient A) and MRI (coronal T2-weighted spectral attenuated inversion recovery [SPAIR]; T1-weighted pre-contrast and postcontrast imaging), which even shows uptake after the administration of paramagnetic contrast material, which is traditionally suggestive of malignancy. Low values at SMI and elastography are suggestive of benignity. Spindle cell lipoma was diagnosed at biopsy, with atypical spindle cell lipomatous tumor in the surgical specimen.](https://img.auntminnie.com/mindful/smg/workspaces/default/uploads/2026/08/images-radiol250278fig2.APCFLSvX6p.jpg?auto=format%2Ccompress&fit=crop&h=112&q=70&w=112)