Tumor > Malignant > Lungcancer

Low Dose Helical CT Screening for Lung Cancer:

The effective radiation dose associated with the low dose screening exam is 0.65 mSv. The approximate dose for conventional CT is 5.8 mSv.

Helical CT: Mayo clinic

Non-contrast exam
7 mm collimation
Pitch 2:1
120 kVp
80 mA
Reconstruct images at 3.5 mm spacing

Helical CT: Henschke CI

Non-contrast exam multidetector camera
2.5 mm collimation
Pitch 1.5
120 kVp
40 mA
Acquire exam in single breath hold (15-20 sec) following hyperventilation

Multislice CT:

High speed mode
5 mm collimation
Table feed 30 mm/sec
120 kVp
40 mA
Reconstruct images at 3.5 mm spacing

REFERENCES:

Society of Thoracic Radiology Course Syllabus 2000; Swenson SJ. Lung cancer screening: Low dose CT. 32-36

Radiology 2004; Henschke CI, et al. C screening for lung cancer: suspiciousness of nodules according to size on baseline scans. 231: 164-168
 