PET/MRI predicts survival in endometrial cancer patients

PET/MRI scans show the progression of endometrial cancer in patients and may help predict survival outcomes, according to a study published September 13 in Academic Radiology.

Researchers led by I-Lun Shih, MD, of National Taiwan University in Taipei, found that certain imaging details on PET/MRI exams were associated with how long patients lived without disease progression. The information could be helpful for determining treatment approaches, they suggested.

"The pathological prognostic factors of endometrial cancer are important for assessing the risk group of patients and determining the need for adjuvant therapy after staging surgery," the group wrote.

Endometrial cancer is the sixth most commonly diagnosed cancer in women worldwide. Imaging biomarkers derived from individual MRI and PET/CT scans have proven valuable in these patients, with MRI used to evaluate the extent of local tumors and PET used to detect the spread of the disease, the authors explained.

However, few studies using integrated PET/MRI scanners – which provide simultaneous MRI and PET data from a single exam – have been conducted to determine the prognostic significance of the approach, they added.

To that end, the researchers performed whole-body PET/MRI exams on 69 patients with a median age of 58 who were newly diagnosed with endometrial cancer. Patients underwent scans before staging surgery to determine the extent of the disease. After treatment, patients were followed up every three months for the first two years, then every six months for five years, and then annually for life.

Images of a 69-year-old woman with endometrial cancer, grade 1 endometrioid adenocarcinoma, T1aN0M0, stage IA. Sagittal (a) and axial (b) T2-weighted MRI show an endometrial tumor (arrow), without deep myometrial invasion. The tumor (arrow) is hyperintense on diffusion-weighted imaging (c) and hypointense on the ADC map (d). The ADCmin of the tumor was 0.45 × 10−3 mm2/s, and the ADCmean was 0.58 × 10−3 mm2/s. PET (e) and PET/MRI fusion images (f) show intense FDG uptake of the tumor (arrow). The SUVmax of the tumor was 12.5, MTV was 3.9 mL, and TLG was 29 g.Images of a 69-year-old woman with endometrial cancer, grade 1 endometrioid adenocarcinoma, T1aN0M0, stage IA. Sagittal (a) and axial (b) T2-weighted MRI show an endometrial tumor (arrow), without deep myometrial invasion. The tumor (arrow) is hyperintense on diffusion-weighted imaging (c) and hypointense on the ADC map (d). The ADCmin of the tumor was 0.45 × 10−3 mm2/s, and the ADCmean was 0.58 × 10−3 mm2/s. PET (e) and PET/MRI fusion images (f) show intense FDG uptake of the tumor (arrow). The SUVmax of the tumor was 12.5, MTV was 3.9 mL, and TLG was 29 g.Image courtesy of Academic Radiology through CC BY 4.0.

After a median follow-up of 80 months, 15 (22%) patients had tumor progression, and six (9%) patients had died. Patients with higher metabolic tumor volume and total lesion glycolysis on the PET/MRI exams had significantly shorter rates of progression-free survival, according to the findings.

The researchers noted that patients with high MTV also had significantly shorter overall survival, with a hazard ratio of 10.84 (p = 0.033).

"This study found that PET/MRI biomarkers in patients with endometrial cancer were associated with pathological prognostic factors, disease progression, and survival," the researchers wrote.

The researchers noted that the cutoff value of metabolic tumor volume for determining prognosis in the study was 32.6 mL, but that further studies are needed to establish a standardized method for measuring metabolic tumor volume and to define the optimal cutoff value.

"This imaging biomarker might provide additional information for the risk stratification of patients," the group concluded.

The full study is available here.

Page 1 of 598
Next Page