POCUS beats landmark guidance for placing arterial lines

2021 04 13 20 42 3667 2021 04 14 Ultrasound Guidance Redo 20210413205433

Placing arterial lines under the guidance of point-of-care ultrasound (POCUS) outperformed traditional landmark guidance in research presented Tuesday at the virtual 2021 American Institute of Ultrasound in Medicine (AIUM) annual meeting.

Research presented by Dr. Ryan Gibbons from Temple University showed that ultrasound guidance led to fewer complications, fewer attempts, and less placement time for interns inserting arterial lines in patients in emergency departments. Gibbons presented findings originally published in September 2020 in the Journal of Emergency Medicine.

Prior to point-of-care ultrasound, landmark guidance was considered the standard of care, but for up to 30% of patients, anatomic landmarks are unreliable, leading to a significant number of complications, Gibbons said. While major complications from landmark guidance are rare, they can lead to vascular injury.

"Furthermore, patient body habitus and hemodynamic instability significantly limit the accuracy of palpation," Gibbons told AuntMinnie.com.

At AIUM 2021, Gibbons discussed results from a randomized controlled trial of 40 patients at Temple University Hospital: 20 patients received ultrasound guidance with a POCUS device, while the other 20 received landmark guidance. The groups were similar in age, sex, and body mass index.

Eighteen novice emergency medicine interns with fewer than 15 previous placements performed the cannulation. They were limited to three attempts or 15 minutes without access and then were instructed to cross over to the other technique.

All 20 patients who received ultrasound guidance had successful cannulation. Meanwhile, only three patients who received landmark guidance saw similar success.

POCUS guidance vs. landmark guidance for arterial placement
  POCUS guidance Landmark guidance p-value
First-pass success rate 75% 0% < 0.0001
Overall success 100% 15% < 0.0001
Attempts (mean) 1.30 2.95 < 0.00001
Time of placement (mean) 264 seconds 524 seconds 0.00424

Some patients with multiple failed attempts at landmark guidance were crossed over to ultrasound guidance; POCUS was 100% successful in these individuals, with a mean of 1.29 attempts and 170 seconds for placement.

Ultrasound guidance proved to be superior to traditional landmark guidance in a randomized trial conducted by researchers at Temple University. Image courtesy of Dr. Ryan Gibbons.Ultrasound guidance proved to be superior to traditional landmark guidance in a randomized trial conducted by researchers at Temple University. Image courtesy of Dr. Ryan Gibbons.

Limitations for the study included patients being unblinded to the fact that the trial was conducted by the Division of Ultrasound, as well as the trial taking place in one center. The researchers also did not account for significant prior point-of-care ultrasound experience.

Gibbons told AuntMinnie.com the team is completing a study comparing ultrasound guidance with landmark guidance in arthrocentesis of medium joints, as well as multicenter studies looking at the role of ultrasound in COVID-19 and cardiac arrest.