Characteristics of studies included in the systematic review

SFM FFDM
Study Location Source population and eligible age group* Study type Equipment and film No. of women/No. of cancers Digital system and viewing modality No. of women/No. of cancers
Lewin et al, 2002 Colorado Population-based screening program; eligible ages, ≥ 40 y (mean, 55.6 y) Prospective paired design GE DMR, Kodak Min-R 2000 film 6,736/33 GE Senographe 2000D, prototype two-monitor workstation, soft-copy reading 6,736/27
Yamada et al, 2004 Miyagi, Japan Population-based screening program; eligible ages, ≥ 50 y Prospective paired design Siemens Mammomat 300 Nova (Mo/Mo, Mo/Rh, Ts/Mo), Kodak Min-R 2000 film 480/2 GE Senographe 2000D (Mo/Mo, Rh/Rh, Mo/Rh), Kodak DryView 8610 laser image unit, hard-copy reading 480/2
Skaane et al, 2005 (Oslo I) Oslo, Norway Population-based screening program; eligible ages, 50-69 y (mean, 58.2 y) Prospective paired design Siemens Mammomat 300 with 29 kV Mo/Mo, Kodak Min-R 2000 film with Min-R 2190 screen 3,683/30§ GE Senographe 2000D in AOP mode, soft-copy reading 3,683/26§
Pisano et al, 2005 (DMIST) 34 centers in the U.S. and Canada Population-based screening programs; eligible ages NA (mean, 54.9 y; IQR: 47, 62) Prospective paired design, random allocation of modality order System routinely used in each center 42,760/174 Five different types of digital mammography with soft- and/or hard-copy reading 42,760/185
Skaane et al, 2007 (Oslo II) Oslo, Norway Population-based screening program; eligible ages 45-69 y (42% were ages 45-49 y) Randomized trial, random allocation stratified by age Siemens Mammomat 300, Kodak Min-R 2000 film and Min-R 2190 screens Ages 45-49 y: 7,082/14; ages 50-69 y: 9,903/50 GE Senographe 2000D, soft-copy reading Ages 45-49 y: 2,935/9; ages 50-69 y: 4,009/32
Del Turco et al, 2007 Florence, Italy Population-based screening program; eligible ages, 50-69 y (47% ages 50-59 y) Two concurrent retrospective cohorts, matched by age and reporting radiologist; allocation to screening modality mainly by residence Siemens Mammomat 1000 14,385/84 GE Senographe 2000D, MammoReport workstation, soft-copy reading 14,385/104
Vigeland et al, 2008 Vestfold County, Norway Population-based screening program (first prevalent two-year round); ages 50-69 y (mean: 59 y) FFDM population: women who attended first prevalent round in Vestfold County; control population: historic database of SFM prevalent two-year round in other 18 counties Siemens Mammomat 300/3000/3000 Nova; GE Senographe DMR, Senographe 800 T; Instrumentarium (Alpha/Diamond); Kodak films (Min-RE, Min-R 2000) 324,763/2,105 Two static Lorad Selenia units (Hologic), flat-panel selenium detectors with 70-µm pixel size, soft-copy reading 18,239/140
Vinnicombe et al, 2008 East London, England Population-based screening program; ages, > 50 y (median, 58 y; IQR: 54, 64) Retrospective cohort; allocation to screening modality mainly by area of residence Two mobile Lorad M IV units 31,718/205 Three GE Senographe DS units, one Lorad Selenia unit 8,475/58
*IQR = interquartile range, NA = not available.
6,736 screening mammograms among 4,489 women.
No screening-detected cancers had occurred up to end of follow-up (the two cancers are diagnostic cases added to the study).
§Includes 10 interval cancers and 16 screening-detected cancers in subsequent round (cancers diagnosed at the initial round: 28 at SFM, 23 at FFDM).
31,718 screening mammograms among 31,385 women at SFM and 8,475 screening mammograms among 8,377 women at FFDM.